AAM GmbH

TENS-, EMS- Incontinence- Tinnitus- and Iontophorese Treatments

reduction of labor ( obstetric ) pain

devices with 4 and 8 electrodes for reduction of:

  • tinnitus, details
  • labor (obstestric) pain
  • amputation pain

devices with 2 outputs and for 4 electrodes
De48.jpg (9903 Byte)

  • CV -, DV - and LV- pain  reduction of back pain with following treatment:              TENS - therapy on back and at the same time muscle build up of the stomach muscles

  • artritis

  • muscle cramps and -tension

  • tear bags

  • for muscle build up

devices with 4 outputs and for 8 electrodes
aam4.jpg (39061 Byte)

  • stimulate tissue metabolism

  • stimulate blood supply

  • tension head ache /  migraine

  • shoulder - Arm - syndrom

  • periartritis

  • epicondolitis

tension head ache / migraine
migrane1.jpg (29128 Byte)

 
  • incontinence

  • menstruation difficulties

  • impotency

 

bladdder incontinence 
inkonvag.jpg (49528 Byte)

 

 

  • hyperhidrosis
  • two- and four cell bath
  • iontophoresis
  • iontophoresis of medicaments
  • low current therapy 0 - 200 µA

 

dc current - devices 0 - 5 mA or 0 - 15 mA, constant current       
22gerat.jpg (35937 Byte)

Tinnitus caused by tension in the shoulder and neck muscles

Very important: according Dr. Weller/ Prof. Dr. Jantsch/ Dr. Schuhfried allowed only to treat with biphasic symmetric ( DC – free ) current

according Dr. Weller/ Prof. Dr. Jantsch/ Dr. Schuhfried allowed only to treat with biphasic symmetric ( DC – free ) current

Treatment time         Pulse width             Frequency                   Programm

      30 min                     100 µsec                10 Hz                            Tinnitus
                                                            or 10 Hz or   20 Hz
                                                            or 50 Hz or 100 Hz

For each patient, it is necessary to experiment with the frequency in order to find the most effective and therapeutic setting. It is best to begin with 10 Hz. In the event that the patient notices no reduction of ear summing, the frequency should be increased.

For tinnitus patients suffering from tension in the neck and shoulder regions, connect the tinnitus electrode on outlet 1 and a TENS electrode pair on outlet 2. Place the TENS electrodes either on the neck muscles, or shoulder muscles. Both therapies can be carried out simultaneously.

The electrodes must not come in contact with the ear drum. The negative electrode will be put behind the ear.

So long the tension of neck - and schoulder muscle are not removed the tinnitus ( ear summing ) will not be reduced.

Average length of treatment: three times daily for circa 3-6 monthsAverage length of treatment: three times daily for circa 3-6 months.

tinnitus.jpg (153653 Byte)

References - Spastic Paresis

References - Tinnitus

References - Pain Therapy

get access to all references

additional Informationen

back

Impressum
AAM Akupunktur- und allgmeiner Medizinbedarf GmbH
Bahnhofstrasse 6
D 88 048 Friedrichshafen

Geschäftsführer: Gerhard Dold
HRB: 991 Amtsgericht Tettnang
ID-Nr: DE 145 374 323

Copyright  © 1999 by AAM GmbH
Stand: 11. 08. 2007
Diese Website wurde erstellt von WeBoNet